price:3.5$~31.75$(depend on specific type)
4-35$per unit
Basic information
usage category | AC-3 | |
Poles size electric current | 32A | |
Rated insulation voltage Ui | AC 690V | |
Rated voltage Ue | AC 690V | |
Rated current Ie | 0.1~32A | |
Operational performance | Operating frequency (times/h) | 120 |
Number of power on operation cycles (times) | 60000 | |
Number of non powered operation cycles (times) | 60000 |
Whether you’re managing industrial machinery or automating building systems, the AC Contactor offers a dependable solution for efficient power management. Choose our AC Contactor for superior performance, durability, and peace of mind.

1 Scope of application
The all-new NXCF series AC contactor has a novel appearance and compact structure. Mainly used for frequent starting and control of AC motors, remote connection and disconnection of circuits, and can be combined with appropriate thermal overload relays to form electromagnetic starters.
Compliant with standards:GB/T 14048.1/IEC 60947-1、GB/T 14048.4/IEC 60947-4-1、 GB/T 14048.5/IEC60947 -5-1、GB 21518.
2 main parameter
2.1 Rated working current Ie:6A~630A
2.2 Rated working voltage Ue:220V~690V
2.3 Rated insulation voltage:690V(NXCF-06(M)~100)、1000V(NXCF-120~630)
2.4 number of poles:3P、4P( 仅 NXCF-06M~12M)
2.5 Coil control method:AC(NXCF-06(M)~225)、DC(NXCF-06M~12M)、AC/DC(NXCF-265~630)
2.6 Installation method:NXCF-06M~100 Installation of card rails and screws、NXCF-120~630 Screw installation
3 Working and installation conditions
Installation category | Working and installation conditions |
Type | Ⅲ |
class of pollution | 3 |
Compliant with standards | GB/T 14048.1/IEC 60947-1、GB/T 14048.4/IEC 60947-4-1、 GB/T 14048.5/IEC 60947-5-1、GB 21518 |
authentication | CE、CCC |
Shell protection level | NXCF-06M~38 is IP20( Only applicable to the front side);NXCF-40~100 is IP10 ;NXCF-120~630 is IP00 |
Surrounding air temperature | The maximum working temperature is -35 ℃~+70 ℃, the normal working temperature is -5 ℃~+40 ℃, and the average value within 24 hours does not exceed+35 ℃. If not used within the normal operating temperature range, please refer to the appendix “Instructions for Non normal Environment Use” for details |
above sea level | Not exceeding 2000m, if not used within this range, refer to the Appendix “Instructions for Abnormal Environment Use” |
Atmospheric conditions | When the maximum temperature is+70 ℃, the relative humidity of the air does not exceed 50%. Higher relative humidity can be allowed at lower temperatures, such as reaching 90% at+20 ℃. Special measures should be taken for occasional condensation caused by humidity changes. |
Installation conditions | The inclination angle between the installation surface and the vertical surface shall not exceed ± 5 ° |
Shock and vibration | The product should be installed and used in a place without significant shaking, impact, and vibration |
control circuit | Contactor model | NXCF-06 | NXCF-09 | NXCF-12 | NXCF-16 | NXCF-18 | NXCF-22 | ||
Main circuit wiring | Cable connection (mm²) | Prefabricated flexible wire | 1 | 1~4 | 1.5~6 | ||||
2 | 1~2.5 | 1.5~4 | |||||||
Hard wire | 1 | 1~4 | 1.5~6 | ||||||
2 | 1~4 | 1.5~6 | |||||||
Tightening screw size | M3.5 | M3.5 | |||||||
Tightening torque (N·m) | 1.2 | 1.2 | |||||||
Control circuit connection | Cable connection (mm²) | Prefabricated flexible wire | 1 | 1~1.5 | |||||
2 | 1~1.5 | ||||||||
Hard wire | 1 | 1~1.5 | |||||||
2 | 1~1.5 | ||||||||
Tightening screw size | M3.5 | ||||||||
Tightening torque (N·m) | 1.2 |
Contactor model | NXCF-06 | NXCF-09 | NXCF-12 | NXCF-16 | NXCF-18 | NXCF-22 | |
Coil control power supply | Inter flow 50Hz | 24、36、42、48、110、120、127、220、230、240、277、380、400、415、440、460、480、525、600、660 | |||||
continuous current | – | ||||||
range of motion | Pull-in | (70%~120%)Us | |||||
Released | (20%~65%)Us | ||||||
Average power consumption of coil (VA) | Open | 50~70 | |||||
Hold | ≤ 9.0 | ≤ 9.5 | |||||
Heat loss rate(W) | alternating | 1~3 | |||||
constant current | – | ||||||
Main contact action time(ms) | close | 12~40 | |||||
Break | 4~25 |
Type | Amax | Bmax | Cmax | Dmax | Emax | Fmax | Gmax | a1 | b1 | C1 | a2 | b2 | C2 | e | f |
NXCF-06~16 | 45.5 | 75 | 88 | 70 | 126.5 | 146.5 | 90 | 35±0.31 | 48±0.31 | Φ4.5 | – | – | – | 10.6 | 7.8 |
NXCF-18~22 | 45.5 | 75 | 88 | 70 | 126.5 | 146.5 | 90 | 35±0.31 | 48±0.31 | Φ4.5 | – | – | – | 11.4 | 9.2 |
NXCF-25~38 | 56.5 | 87 | 93 | 81 | 131.5 | 151.5 | 95 | 40±0.31 | 48±0.31 | Φ4.5 | – | – | – | 14.2 | 10.6 |
NXCF-40~65 | 77 | 129 | 118 | 102 | 156.5 | 176.5 | 121 | 40±0.28 | 105±0.57 | Φ6.5 | 64 | 105 | Φ6 | 20 | 9.5 |
NXCF-75~100 | 87 | 132 | 127 | 112 | 165.5 | 185.5 | 129 | 40±0.28 | 105±0.57 | Φ6.5 | 74 | 112 | Φ6.2 | 24 | 13 |
above sea level(m) | 2000 | 3000 | 4000 | 5000 |
Rated impulse withstand voltage correction factor | 1 | 0.88 | 0.78 | 0.7 |
Rated working current correction factor | 1 | 0.92 | 0.9 | 0.85 |
Instructions for use in abnormal temperature environments
- The GB/T 14048.1 standard specifies the normal working environment temperature of the product, and its use within the normal working environment temperature range has no significant impact on product performance.
- When the working environment temperature is higher than+40 ℃, it is necessary to consider that the allowable limit temperature rise of the product must be reduced. The rated working current must be lowered, and the number of contactors installed in standard components must be reduced. Otherwise, it may damage, shorten the product life, and reduce work reliability, and also affect the product’s operating range; When the working environment temperature is below -5 ° C, it should be considered that the grease used for insulation and lubrication will freeze at low ambient temperatures, leading to product malfunction. Therefore, manufacturers and users need to negotiate for design or use.
- The following table shows the correction factors for the rated working current when the working environment temperature exceeds+55 ℃ and the rated working voltage remains unchanged.
Temperature(℃) | 55 | 60 | 65 | 70 |
correction factor | 1 | 0.93 | 0.875 | 0.75 |
The AC Contactor is a reliable and efficient electrical device designed for controlling and switching AC power circuits in a wide range of industrial, commercial, and residential applications. Built with high-quality materials and advanced engineering, it ensures safe and durable operation under various load conditions.
Key Features:
- Robust Construction: Designed to withstand high electrical loads and harsh environments.
- Easy Installation: Compact and user-friendly design for quick and hassle-free setup.
- Energy Efficiency: Low power consumption, contributing to reduced operational costs.
- Wide Compatibility: Suitable for use with motors, lighting systems, heaters, and other AC-powered equipment.
- Safety Assurance: Equipped with overload protection and arc suppression mechanisms to ensure safe operation.
Whether you’re managing industrial machinery or automating building systems, the AC Contactor offers a dependable solution for efficient power management. Choose our AC Contactor for superior performance, durability, and peace of mind.