Our relay is an electrically operated switch. It consists of a control circuit and a load circuit. In the control circuit, a relatively small electrical current is used. When this current is applied, it activates an electromagnet within the relay. The electromagnet then causes a mechanical movement which closes or opens the contacts in the load circuit. Relays are widely used in various electrical systems. In automotive electronics, they can be used to control high power devices such as headlights or the starter motor. In industrial control systems, relays are often used for isolation between different parts of a circuit, protecting sensitive components from high voltage or high current surges. They also play an important role in automation processes, allowing for the control of multiple devices based on different electrical signals.

new design factory price relay DC12VA

PCB relay JQC-3FF Series product specification

  •  10Aswitchingcapability
  • Small footprint
  • Sealed typeavailable
  • ClassB/F available
  • Conform toRoHS, ELV directive
  • Size19. 2mm*15.4mm*15.4mm(Length * Width * Height)

Declaration: This product specification is for reference only for customers to use. Any changes will not be notified separately.

new design factory price relay DC12VA

ORDERING CODE

JQC  3FF – S – H

1           2   3

1 . Relay Model JQC-T73

2: S: sealed

3 . Touch point conversion form Z: Form C   H: Form A   D:FormB

COIL DATA( at 20℃ )

Nominal Voltage  (VDC) 5 6 9 12 18 24 48 0 . 36W
Coil Resistance  (Ω±10%) 69 100 225 400 900 1600 6400
Rated Current  (mA) 71.4 60 40 30 20 15 7. 5
Max Operate Voltage  (VDC) 3 .75 4 . 5 6 .75 9 13 . 5 18 36
Min Release Voltage  (VDC) 0 . 25 0 . 3 0 .45 0.6 0 . 9 1 . 2 2 .4
Coil Resistance  (Ω±10%) 55 80 180 320 720 1280 5120 0.45W
Rated Current  (mA) 89.3 75 50 37.5 25 18.7 9.375
Max Operate Voltage  (VDC) 3.8 4.5 6.8 9 13.5 18 36
Min Release Voltage  (VDC) 0.5 0.6 0.9 1.2 1.8 2.4 4.8
Max Applicable Voltage 130% of the rated voltage at 70°C, 170% of the rated voltage at 23°C

CONTACT DATA 

Contact  Form 1H/1Z
Contact  Material Silver Alloy
Load Resistive  load( COS Ф =1)
Contact  Ratings 20A 125VAC

20A 14VDC

Minimum load 100mA 5VDC
Max Switching Voltage 250VAC/30VDC
Max Switching Current 15A
Max Switching Power 2500VA/240W
Contact Resistance 100mΩMax           at 6VDC 1A
Life Expectancy Electrical : 100,000  Operations(at30Operations/minute)
Mechanical : 10,000,000 Operations(at300Operations/minute)

CHARACTERISTICS DATA

Insulation Resistance 100MΩMin at 500VDC
Dielectric Strength Between Open Contacts 750VAC(50/60Hz for one minute)
Between Contacts and coil 1500VAC(50/60Hz for one minute)
Operate Time 10ms
Release Time 5ms
Temperature Range -40℃ to+85℃
Shock Resistance Operating Extremes  : 10G
Damage Limits   : 100G
Vibration Resistance 10-55Hz, 1.5mm
Max. switching frequency Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr
Humidity 40-85%
Weight Approx 10g
Safety Standard CQC

    new design factory price relay DC12VA

    1. The dimension tolerance is not noted in the external dimension of the product: when the dimension is 1mm, the tolerance is ± 0.2mm; when the dimension is 1~5mm, the tolerance is ± 0.3mm; when the dimension is> 5mm, the tolerance is ± 0.4mm.
    2. The tolerance of the unlisted dimension in the installation hole size is ± 0.1mm.

     Others

    1.All the performance data listed in the data sheet are the initial values tested under standard testing condition.

    2.Unsealed relays should be hand soldered to avoid flux contamination of the relay.

    3.To avoid using relays under strong magnetic field because it will change the parameters of relay such as pull-in and drop-out voltage.

    4.To maintain the performances of relays, please do not make the relay drop or be shocked strongly Suggest that the relays dropped not be used.