1 Scope of application
The all-new NXCF series AC contactor has a novel appearance and compact structure. Mainly used for frequent starting and control of AC motors, remote connection and disconnection of circuits, and can be combined with appropriate thermal overload relays to form electromagnetic starters.
Compliant with standards:GB/T 14048.1/IEC 60947-1、GB/T 14048.4/IEC 60947-4-1、 GB/T 14048.5/IEC60947 -5-1、GB 21518.
2 main parameter
2.1 Rated working current Ie:6A~630A
2.2 Rated working voltage Ue:220V~690V
2.3 Rated insulation voltage:690V(NXCF-06(M)~100)、1000V(NXCF-120~630)
2.4 number of poles:3P、4P( 仅 NXCF-06M~12M)
2.5 Coil control method:AC(NXCF-06(M)~225)、DC(NXCF-06M~12M)、AC/DC(NXCF-265~630)
2.6 Installation method:NXCF-06M~100 Installation of card rails and screws、NXCF-120~630 Screw installation
3 Working and installation conditions
Installation category | Working and installation conditions |
Type | Ⅲ |
class of pollution | 3 |
Compliant with standards | GB/T 14048.1/IEC 60947-1、GB/T 14048.4/IEC 60947-4-1、 GB/T 14048.5/IEC 60947-5-1、GB 21518 |
authentication | CE、CCC |
Shell protection level | NXCF-06M~38 is IP20( Only applicable to the front side);NXCF-40~100 is IP10 ;NXCF-120~630 is IP00 |
Surrounding air temperature | The maximum working temperature is -35 ℃~+70 ℃, the normal working temperature is -5 ℃~+40 ℃, and the average value within 24 hours does not exceed+35 ℃. If not used within the normal operating temperature range, please refer to the appendix “Instructions for Non normal Environment Use” for details |
above sea level | Not exceeding 2000m, if not used within this range, refer to the Appendix “Instructions for Abnormal Environment Use” |
Atmospheric conditions | When the maximum temperature is+70 ℃, the relative humidity of the air does not exceed 50%. Higher relative humidity can be allowed at lower temperatures, such as reaching 90% at+20 ℃. Special measures should be taken for occasional condensation caused by humidity changes. |
Installation conditions | The inclination angle between the installation surface and the vertical surface shall not exceed ± 5 ° |
Shock and vibration | The product should be installed and used in a place without significant shaking, impact, and vibration |
Model Description
Note: The 06A-100A specification product comes with 1 normally open and 1 normally closed auxiliary contact.
Model example: NXCF-12 220V indicates that the rated working current of the contactor is 12A when the main circuit voltage is 380V/400V under the AC-3 usage category. Each contactor body is equipped with 1 normally open and 1 normally closed auxiliary contact, and the coil control voltage is 220V AC with a frequency of 50Hz.
NXCF Series Selection Table for AC Contactors.
Main Parameters and Technical Performance
Main circuit parameters and technical performance
Contactor model | NXCF-06 | NXCF-09 | NXCF-12 | NXCF-16 | NXCF-18 | NXCF-22 | ||
Shell level | 06~16 | 18~22 | ||||||
Agreed free air heating current Ith(A) | 20 | 20 | 25 | 25 | 32 | 32 | ||
Rated insulation voltage Ui(V) | ||||||||
Rated impulse withstand voltage Ui mp(kV) | 8 | |||||||
Rated connection capacity | current on:10×Ie(AC-3) or 12×Ie(AC-4) | |||||||
Rated breaking capacity | Connect breaking current:8×Ie(AC-3) or 0×Ie(AC-4) | |||||||
Rated working current
Ie(A) |
AC-1 | 20 | 20 | 25 | 25 | 32 | 32 | |
220V/230V | AC-3 | 6 | 9 | 12 | 16 | 18 | 22 | |
AC-4 | 6 | 9 | 12 | 16 – | 18 | 22 | ||
380V/400V | AC-3 | 6 | 9 | 12 | 16 | 18 | 22 | |
AC-4 | 6 | 9 | 12 | 12 | 18 | 18 | ||
660V/690V | AC-3 | 3.8 | 6.6 | 8.9 | 8.9 | 12 | 14 | |
AC-4 | 3.8 | 6.6 | 8.9 | 8.9 | 12 | 12 | ||
Rated control power | AC-3(kW) | 220V/230V | 1.5 | 2.2 | 3 | 3 | 4 | 5.5 |
380V/400V | 2.2 | 4 | 5.5 | 7.5 | 7.5 | 11 | ||
660V/690V | 3 | 5.5 | 7.5 | 7.5 | 10 | 11 | ||
Electrical lifespan (10000 cycles) | AC-3 | 120 | ||||||
AC-4 | The specific information is in the electrical life curve chart | |||||||
Mechanical lifespan (1000 cycles) | 12 000 | |||||||
Main contact structure type | 3 normally open | |||||||
SCPD Used fuses | gG20 | gG20 | gG25 | gG25 | gG32 | gG32 | ||
Matching thermal overload relay | Type | NXRF-25 | ||||||
Number of built-in auxiliary contacts | 3P | 1 open 1 close | ||||||
4P | – |
control circuit | Contactor model | NXCF-06 | NXCF-09 | NXCF-12 | NXCF-16 | NXCF-18 | NXCF-22 | ||
Main circuit wiring | Cable connection (mm²) | Prefabricated flexible wire | 1 | 1~4 | 1.5~6 | ||||
2 | 1~2.5 | 1.5~4 | |||||||
Hard wire | 1 | 1~4 | 1.5~6 | ||||||
2 | 1~4 | 1.5~6 | |||||||
Tightening screw size | M3.5 | M3.5 | |||||||
Tightening torque (N·m) | 1.2 | 1.2 | |||||||
Control circuit connection | Cable connection (mm²) | Prefabricated flexible wire | 1 | 1~1.5 | |||||
2 | 1~1.5 | ||||||||
Hard wire | 1 | 1~1.5 | |||||||
2 | 1~1.5 | ||||||||
Tightening screw size | M3.5 | ||||||||
Tightening torque (N·m) | 1.2 |
Contactor model | NXCF-06 | NXCF-09 | NXCF-12 | NXCF-16 | NXCF-18 | NXCF-22 | |
Coil control power supply | Inter flow 50Hz | 24、36、42、48、110、120、127、220、230、240、277、380、400、415、440、460、480、525、600、660 | |||||
continuous current | – | ||||||
range of motion | Pull-in | (70%~120%)Us | |||||
Released | (20%~65%)Us | ||||||
Average power consumption of coil (VA) | Open | 50~70 | |||||
Hold | ≤ 9.0 | ≤ 9.5 | |||||
Heat loss rate(W) | alternating | 1~3 | |||||
constant current | – | ||||||
Main contact action time(ms) | close | 12~40 | |||||
Break | 4~25 |
Type | Amax | Bmax | Cmax | Dmax | Emax | Fmax | Gmax | a1 | b1 | C1 | a2 | b2 | C2 | e | f |
NXCF-06~16 | 45.5 | 75 | 88 | 70 | 126.5 | 146.5 | 90 | 35±0.31 | 48±0.31 | Φ4.5 | – | – | – | 10.6 | 7.8 |
NXCF-18~22 | 45.5 | 75 | 88 | 70 | 126.5 | 146.5 | 90 | 35±0.31 | 48±0.31 | Φ4.5 | – | – | – | 11.4 | 9.2 |
NXCF-25~38 | 56.5 | 87 | 93 | 81 | 131.5 | 151.5 | 95 | 40±0.31 | 48±0.31 | Φ4.5 | – | – | – | 14.2 | 10.6 |
NXCF-40~65 | 77 | 129 | 118 | 102 | 156.5 | 176.5 | 121 | 40±0.28 | 105±0.57 | Φ6.5 | 64 | 105 | Φ6 | 20 | 9.5 |
NXCF-75~100 | 87 | 132 | 127 | 112 | 165.5 | 185.5 | 129 | 40±0.28 | 105±0.57 | Φ6.5 | 74 | 112 | Φ6.2 | 24 | 13 |
1:Instructions for use in abnormal environments
Explanation of using correction factors in high-altitude areas
- The GB/T 14048.1 standard specifies the relationship between altitude and impulse withstand voltage. When the altitude is ≤ 2000m, it has no significant impact on product performance.
- When the altitude is greater than 2000m, the air cooling effect and the decrease in rated impulse withstand voltage must be considered, so the manufacturer needs to negotiate with the user for design or use.
- The following table provides the correction factors for the rated impulse withstand voltage and rated working current at an altitude greater than 2000m and with the rated working voltage unchanged.
above sea level(m) | 2000 | 3000 | 4000 | 5000 |
Rated impulse withstand voltage correction factor | 1 | 0.88 | 0.78 | 0.7 |
Rated working current correction factor | 1 | 0.92 | 0.9 | 0.85 |
- After parallel connection of poles, considering the distribution of long-term unstable currents, the rated current of parallel poles needs to be adjusted, as shown in the table below:
Parallel series | 2 | 3 | 4 |
correction factor | 1.6 | 2.25 | 2.8 |
Note: If the product is applied in a dusty environment,Please select and install a dust cover AXC-1、AXC-2、AXC-3、AXC-4。