A relay is an electrically operated switch. It consists of a control circuit and a load circuit. When a small electric current passes through the control circuit, it can cause the relay to close or open the contacts in the load circuit. This allows a relatively small electrical signal to control a much larger current or voltage in another circuit. Relays are widely used in various electrical and electronic systems. For example, in industrial control systems, they can be used to start or stop motors. In automotive electronics, relays are often used to control high power components such as headlights and horns. They play an important role in ensuring the normal operation and safety of electrical equipment.

basic information

Contact MaterialAgSn012
Contact Form1Z(1C)\1H(1A)
Contact RatingsN0:80A14VDC
Contact Resistance100mMax    at6VDC 1A
Max Switching Current80A
Max Switching Voltage75VDC
Max Switching Power80A
Life Expectancy Electrical                                                                            100,000  Operations(at300perations/minute)
Life Expectancy Machanical10,000,0000perations

DC48V Welding relay for headlight air conditioning

DC48V Welding relay for headlight air conditioning

DC48V Welding relay for headlight air conditioning

DC48V Welding relay for headlight air conditioning

SPECIFICATION

1.CONTACT DATA

Contact MaterialAgSn012
Contact Form1Z(1C)\1H(1A)
Contact RatingsN0:80A14VDC
Contact Resistance100mMax    at6VDC 1A
Max Switching Current80A
Max Switching Voltage75VDC
Max Switching Power80A
Life Expectancy Electrical                                                                            100,000  Operations(at300perations/minute)
Life Expectancy Machanical10,000,0000perations

2.COIL SPECIFICATION

Nominal Voltage (VDC)Coil Resistance

(Ω)

Max Operate

Voltage (VDC)

Mix Release Voltage

(VDC)

Max Applicable Voltage

(VDC)

1.8w
12806.0~8.00.6~3.615.6
2432012~16.01.2~7.231.2

3.CHARACTERISTICS:

Temperature Range-30℃~+80℃
Vibration Resistance10~55Hz,1.5mm
Shock ResistanceOperations Extremes10g
Damage Limits100g
Humidity40%~85%
Insulation Resistance100mQ Min   at500VDC
Safety StandardCCEE
Dielectric Strength Between Open Contacts500VAC(for one minute/sec)
Between Contact and coil750VAC(for one minute/sec
Operate Time7ms
Release Time5ms
Weight35g Apptox

Relays Model 

DC48V Welding relay for headlight air conditioningDC48V Welding relay for headlight air conditioningDC48V Welding relay for headlight air conditioningDC48V Welding relay for headlight air conditioning